19
18
The level of soft ice cream is set to default by the manufacturer, but you need to
change the level suitable to the type of ingredient and wear of the blade.
The ingredient value should stay at the manufacturer’s default value; if change of the
value is needed, please consult an expert.
For Your
Information
Detailed description of each mode
② “Press “SELECT” to see the current level, target level,
and no-load level in turn.
Hold down SET for about 3 seconds to change
the configured values.
(Refer to the “Checking the configured values”section
of this manual for details.).
[ A u t o ] I c e c r e a m L e v e l
[ A u t o ]
[ T e m p e r a t u r e ]
N o w L o a d : 1 . 20 A / 1 . 20 A
S e t L o a d : 1 . 50 A / 1 . 5 0 A
N o L o a d : 1 . 00 A / 1 . 0 0 A
H o p p e r : 8 . 2 °C / 8 . 2 °C
D r u m : - 6 . 2 °C / - 6 . 2 °C
8 . 0 m i n / 8 . 0 m i n
②
Put ingredient into the hopper and press “DEC.” The display
shows the information presented in the figure on the right.
Soft ice cream is being made in“AUTO”mode.
“For checking the configured values of“AUTO”mode
“For checking the ingredient information in“AUTO”mode
“After making soft ice cream in “AUTO” mode
① Shows the current level of soft ice cream
To check the ingredient information in the hopper, press
“SET” to change the display to that shown in the figure
on the right.
③ Shows information including the temperature of the hopper
and cylinder.Press and hold down the “SET” button for 3
seconds to change the temperature setting of the hopper.
(Refer to the “Checking the configured values” section
of this manual for details.)
④ The time (in minutes) required to reactivate the compressor
is displayed.(If the temperature of the room is high enough,
the compressor may get reactivated earlier than the minutes
displayed.)
⑤ Shows the current level of soft ice cream. (The level goes
down after reaching 100%; the speed of decrease will be
higher if the temperature of the room is high.)
After making soft ice cream, the compressor goes into
hibernation for a certain period with the display window
shown in the figure on the right.
④
⑤
③
【
Detailed description of each mode
】
[ A u t o ] I c e c r e a m L e v e l
6 0 % / 6 0 %
M i d d l e
1 . 5
[ A ]
B r e a k T i m e
8 . 0 m i n / 8 . 0 m i n
①
6 0 % / 6 0 %
M i d d l e
1 . 5
[ A ]
B r e a k T i m e
Содержание ISI-273SH3S
Страница 12: ...12 LEFT SIDE RIGHT SIDE Description of parts 900 ISI 273SH3S ISI 273SHW3S Drain slug Air cooling Water cooling...
Страница 13: ...13 BACK Description of parts ISI 273SH3S ISI 273SHW3S Pressure gauge Air cooling Water cooling...
Страница 54: ...54 MEMO...
Страница 55: ...55 MEMO...
Страница 56: ...3240273 00 Online Internet Service http www icetro com...