Error code type
◆
Resolution
Even though the product is functioning normally, unfamiliarity with the product or any trivial factor may cause
malfunction. Contact the customer service center if the troubleshooting does not work, the error code is not included
in the list, or the same error occurs repeatedly. Before contacting the service center, turn off the maker, wait for
5 minutes, and turn it on and operate again.
Error code
Cause
Troubleshooting
Deactivation Operation
Er00
Mix Out
No ingredient
Refill the hopper with ingredient.
Automatically deactivated
Stop
Er01
Hop. Sensor Op.
Cooling sensor OPEN
Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Er02
Hop. Sensor St.
Cooling sensor SHORT
Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Er03
Cyl. Sensor Op.
Cooling sensor OPEN
Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Er04
Cyl. Sensor St.
Cooling sensor SHORT
Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Er07
EOCR
Overcurrent detected with the motor
(overcooling)
Melt the ice cream and run the maker again.
Deactivated after resetting
Resetting
Er08
High Pressure
Overvoltage detected
Clean the filter and check the ventilation hole and water supply.
Automatically deactivated
Stop
Er09
noLA
Not forming
Issue with coolant (Contact the service center.)
Automatically deactivated
Operation
Er10
Low Voltage
Supplied voltage exceeded more than -15%
Power supply issue (Contact the service center.)
Automatically deactivated
Stop
Er11
High Voltage
Supplied voltage exceeded more than 15%
Power supply issue (Contact the service center.)
Automatically deactivated
Stop
Er13
Condensor OH
Condenser temperature too high
Check if the ventilation hole is clogged.
Automatically deactivated
Operation
Er14
Motor Belt Er.
Power axis issue
Melt the ice cream and run the maker again. Deactivated after resetting
Resetting
Er15
EEPROM Error
EEPROM issue
PCB issue (Contact the service center.)
Reset power
Operation
Er17
Heating Error
Pasteurization issue
Replace the ingredient and clean the product.
Abnormal operation
Operation
Er18
Cover Error
Dasher cover issue
Make sure the cover is correctly assembled.
Automatically deactivated
Stop
Er21
Motor Power Er.
Motor current not detected
Product issue (Contact the service center.)
Deactivated after resetting
Resetting
Er22
Power Fail Er.
Power goes off.
Power blackout (No action to be taken)
Deactivated after resetting
Operation
Er30
Vend Error
Product issue
PCB issue (Contact the service center.)
Deactivated after resetting
Stop
Er31
Top Sensor Er.
TOP sensor issue
Remove foreign object from the cup holder part. Deactivated after resetting
Stop
Er32
Down Sensor Er.
DOWN sensor error
Remove foreign object from the cup holder part. Deactivated after resetting
Stop
Er33
Piston NO Er.
NO input from piston
Sensor malfunction (Contact the service center.)
Deactivated after resetting
Stop
Er34
Piston NC Er.
NC input from piston
Sensor malfunction (Contact the service center.)
Deactivated after resetting
Stop
Er44
Vend Comm.
Vend PCB communication error PCB issue (Contact the service center.)
Automatically deactivated
Stop
Er50
Power IC Er.
Power IC issue
Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Er51
Invertor DE Er.
Inverter out of order
Product issue (Contact the service center.)
Automatically deactivated
Stop
Er52
Invertor Comm.
Inverter communication error Sensor malfunction (Contact the service center.)
Automatically deactivated
Stop
Содержание ISI-273SH3S
Страница 12: ...12 LEFT SIDE RIGHT SIDE Description of parts 900 ISI 273SH3S ISI 273SHW3S Drain slug Air cooling Water cooling...
Страница 13: ...13 BACK Description of parts ISI 273SH3S ISI 273SHW3S Pressure gauge Air cooling Water cooling...
Страница 54: ...54 MEMO...
Страница 55: ...55 MEMO...
Страница 56: ...3240273 00 Online Internet Service http www icetro com...