21
20
DEC.
L/R
SET
INC.
SELECT
Detailed description of each mode
Press the “SET” button to shift to the mode of
checking the values of the maker.
Press “INC” or “DEC” after shifting to this mod
to check the configured values in the following order:
The configured temperatures of the hopper
and cylinder are displayed.
The rated voltage, frequency, and current supplied
to the product are displayed.
The versions of programs for the main PCB, vend PCB,
and control PCB in the product are displayed.
The time and date set for the product are displayed.
The unloaded current value of the dasher motor
is displayed.
First : Unloaded current for the initial control of ice cream
Run : Unloaded current for the initial control of ice cream
during operation
Draw : Unloaded current for projecting ice cream
【
Checking the configured values
】
[ P o w e r ]
[ V e r s i o n ]
[ C u r r e n t t i m e ]
[ N o l o a d C u r r e n t ]
[ T e m p e r a t u r e ]
H o p p e r : 8 . 2 °C / 8 . 2 °C
D r u m : - 6 . 2 °C / - 6 . 2 °C
V o l t a g e : 2 2 0 V
F r e q u e n c y : 6 0 H z
C u r r e n t : 1 . 2 0 A / 1 . 2 0 A
M a i n : 1 . 0 V e n d : 1 . 0
C o n t r o l : 1 . 0 / 1 . 0
D o o r :
F i r s t : 3 . 0 A
R u n : 3 . 0 A
D r a w : 2 . 1 A
2 0 1 2. 1 2. 0 3
1 7 : 0 1 : 0 2
Cold preservation of cylinder after completing “PASTEURIZE”