MAP 0170: Thin Processor Node Control
003 (continued)
Was mode originally in SERVICE position as noted in previous step?
Yes No
004
Customer may have tried to reset processor node in SECURE mode. Reset will only take
effect in NORMAL or SERVICE modes.
– From the control workstation, reset this processor node.
Does processor node reset?
Yes No
005
Problem with reset.
– Go to Step 012 on page 1-76.
006
No problem found.
– Inform customer that the processor node will not reset if the mode switch is in the SECURE
position.
– Go to “MAP 0570: End of Call” on page 1-357.
007
– From the control workstation, issue reset for this processor node.
Does processor node reset?
Yes No
008
Problem with reset.
– Go to Step 012 on page 1-76.
009
Intermittent problem may be occurring.
– Please record following:
Node number
Date / Time fault reported
Type of fault reported
– Check logs to see if this fault has been previously recorded.
Is this a recurring fault?
Yes No
010
This is not a recurring fault.
– Go to “MAP 0570: End of Call” on page 1-357.
011
Reoccurrence of intermittent fault has been detected.
(Step 011 continues)
Chapter 1. Maintenance Analysis Procedures (MAPs)
1-75
Содержание RS/6000 SP
Страница 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Страница 2: ......
Страница 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Страница 8: ...vi RS 6000 SP MAPs...
Страница 10: ...viii RS 6000 SP MAPs...
Страница 16: ...xiv RS 6000 SP MAPs...
Страница 20: ...xviii RS 6000 SP MAPs...
Страница 60: ...MAP 0130 Processor Node Figure 1 7 Thin Node High Level Diagram 1 40 RS 6000 SP MAPs...
Страница 64: ...MAP 0130 Processor Node Figure 1 11 604 or 604e High Node High Level Component Diagram 1 44 RS 6000 SP MAPs...
Страница 196: ...MAP 0300 332 MHz SMP Node Power 064 continued Go to Step 008 on page 1 169 1 176 RS 6000 SP MAPs...
Страница 383: ......
Страница 387: ......