MAP 0170: Thin Processor Node Control
Priority
Component
Action
1
Cable N00-NS-P104 to N00-PL-P16
1. Check for proper seating. If no problem found, con-
tinue at Priority 2.
2. Repair or replace cable assembly as required.
3. Go to Step 031 on page 1-80 to verify fix.
2
Node Supervisor Card
1. Replace card.
2. Perform "Verification Test for Supervisor Bus" in
IBM RS/6000 SP: Maintenance Information,
Volume 3, Locations and Service Procedures.
3. Go to Step 031 on page 1-80 to verify fix.
3
Planar Board
1. Replace board.
2. Go to Step 031 on page 1-80 to verify fix.
4
All replaced
Call next level of support.
031
Component has been repaired or replaced.
– Remove processor node from service position.
– Reconnect all cables at rear of the processor node.
– As processor node completes IPL, check the TTY console window.
– From the control workstation node front panel display, put the processor node in SERVICE mode.
– Put the circuit breaker at the front of the processor node in the On (‘1’) position.
Do you get any data on the TTY console screen?
Yes No
032
– Go to Step 030 on page 1-79 to service the next highest priority component.
033
Processor node IPLed in SERVICE mode.
– From the TTY console:
Select “Advanced Diagnostic Routines”
Select “System Verification”
Select “Base System”
Does processor node pass all diagnostics?
Yes No
034
– Repair problem as indicated by diagnostics. Use “MAP 0130: Processor Node” on page 1-30 as
necessary.
035
Problem resolved.
– Reboot node in NORMAL mode.
– Log into the node over the Ethernet:
telnet
nodename
(Step 035 continues)
1-80
RS/6000 SP MAPs
Содержание RS/6000 SP
Страница 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Страница 2: ......
Страница 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Страница 8: ...vi RS 6000 SP MAPs...
Страница 10: ...viii RS 6000 SP MAPs...
Страница 16: ...xiv RS 6000 SP MAPs...
Страница 20: ...xviii RS 6000 SP MAPs...
Страница 60: ...MAP 0130 Processor Node Figure 1 7 Thin Node High Level Diagram 1 40 RS 6000 SP MAPs...
Страница 64: ...MAP 0130 Processor Node Figure 1 11 604 or 604e High Node High Level Component Diagram 1 44 RS 6000 SP MAPs...
Страница 196: ...MAP 0300 332 MHz SMP Node Power 064 continued Go to Step 008 on page 1 169 1 176 RS 6000 SP MAPs...
Страница 383: ......
Страница 387: ......