Form factor
Short, low-profile
FC compatibility
4, 8, 16 Gb
Cables
Cables are the responsibility of the customer. Use multimode fiber optic cables with shortwave lasers
that adhere to the following specifications:
• OM4: Multimode 50/125 micron fiber, 4700 MHz x km bandwidth
• OM3: Multimode 50/125 micron fiber, 2000 MHz x km bandwidth
• OM2: Multimode 50/125 micron fiber, 500 MHz x km bandwidth
• OM1: Multimode 62.5/125 micron fiber, 200 MHz x km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best
results, OM2 cables must not be connected to OM3 cables. However, if an OM2 cable is connected to
an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables.
The following table shows the supported distances for the different cable types at the different link
speeds.
Table 14. Supported distances for cables
Header
Cable type and distance
Rate
OM1
OM2
OM3
OM4
4 Gbps
0.5 - 70 m (1.64 -
229.65 ft)
0.5 - 150 m (1.64
- 492.12 ft)
0.5 - 380 m (1.64
- 1246.71 ft)
0.5 - 400 m (1.64
- 1312.34 ft)
8 Gbps
0.5 - 21 m (1.64 -
68.89 ft)
0.5 - 50 m (1.64 -
164.04 ft)
0.5 - 150 m (1.64
- 492.12 ft)
0.5 - 190 m (1.64
- 623.36 ft)
16 Gbps
0.5 - 15 m (1.64 -
49.21 ft)
0.5 - 35 m (1.64 -
114.82 ft)
0.5 - 100 m (1.64
- 328.08 ft)
0.5 - 125 m (1.64
- 410.10 ft)
Adapter LED states
Green and yellow LEDs can be seen through openings in the mounting bracket of the adapter. Green
indicates firmware operation, and yellow signifies port activity. Table 15 on page 61 summarizes normal
LED states. A 1 Hz pause occurs when the LED is off between each group of fast flashes (2, 3 or 4).
Observe the LED sequence for several seconds to ensure that you correctly identify the state.
Table 15. Normal LED states
Green LED
Yellow LED
State
On
2 fast flashes
4 Gbps link rate: normal, link
active
On
3 fast flashes
8 Gbps link rate: normal, link
active
On
4 fast flashes
16 Gbps link rate: normal, link
active
Power-on-self-test (POST) conditions and results are summarized in Table 16 on page 62. These states
can be used to identify abnormal states or problems.
Installing and configuring the 8335-GTX 61
Содержание Power System AC922
Страница 1: ...Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX IBM...
Страница 4: ...iv...
Страница 14: ...xiv Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX...
Страница 105: ...or or or or Installing and configuring the 8335 GTX 91...
Страница 121: ...Figure 54 Routing the power cord loop in the cable management arm Installing and configuring the 8335 GTX 107...
Страница 126: ...112 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX...
Страница 137: ......
Страница 138: ...IBM...