About the Test Programs
Using the Command Line Options
The following Command Line Options allow you to define specific
conditions for running the diagnostic programs at startup time.
At the operating system prompt, type
QAPRO /XXX
(where
/XXX
represents one of the following from the list below); then, press
Enter:
/B&W
The /B&W option forces the program to load
in black and white (monochrome) mode.
/LOG=
file
The /LOG=file option directs the test programs
to start using a specified Error Log file.
/INT10
The /INT10 option forces the test programs to
use the Basic Input/Output System (BIOS) for
screen writes.
/O
XXX
The /OXXX option, where XXX=test group
(for example, MBD/MEM/VID/HDU/FDU
/KBD/COM/LPT, and so on), omits the
designated test group from testing. (See
/I
XXX for a list of valid test groups.)
/OALL
The /OALL option omits all test groups from
testing. (See /IXXX for more information.)
/I
XXX
The /IXXX option, where XXX=test group,
includes the designated test group. When
used in conjunction with the /OALL option,
you can specify the tests that you want to
include. These options are helpful if you have
insufficient memory available to load all of the
test programs simultaneously, or if you want
to test specific test groups.
The valid test groups are:
LPT
Parallel port
COM
Serial ports
HDU
Hard disk (IDE only)
FDU
Diskette drive
VID
Video
MBD
System board
218
PC Server 704 User's Handbook
Содержание PC Server 704
Страница 1: ...PC Server 704 User s Handbook IBM...
Страница 332: ...IBM Part Number 30F6951 Printed in U S A March 1997 3 F6951...