Table
3.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
(Trained
service
technician
only),
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
codes
Description
Action
604
An
error
occurred
during
a
diskette
drive
test.
1.
Make
sure
that
the
Configuration/Setup
Utility
program
correctly
reflects
the
type
of
diskette
drive
that
you
have
installed.
2.
Make
sure
that
the
diskette
drive
cables
are
correctly
and
securely
connected.
3.
Reseat
the
following
components:
a.
Diskette
drive
b.
(Trained
service
technician
only)
System
board
4.
Run
the
diagnostic
tests.
If
the
computer
fails
the
diagnostic
tests,
replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Diskette
drive
b.
(Trained
service
technician
only)
System
board
662
A
diskette
drive
configuration
error
occurred.
1.
If
you
removed
a
diskette
drive,
make
sure
that
the
diskette
drive
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it
and
save
the
setting.
2.
Make
sure
that
the
diskette
drive
cables
are
correctly
and
securely
connected.
3.
Reseat
the
following
components:
a.
Diskette
drive
b.
(Trained
service
technician
only)
System
board
4.
Run
the
diagnostic
tests.
If
the
computer
fails
the
diagnostic
tests,
replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Diskette
drive
b.
(Trained
service
technician
only)
System
board
962
A
parallel
port
configuration
error
occurred.
If
you
changed
a
hardware
option,
make
sure
that
the
parallel
port
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it
and
save
the
setting.
1162
The
serial
port
configuration
conflicts
with
another
device
in
the
system.
1.
Make
sure
that
the
IRQ
and
I/O
port
assignments
needed
by
the
serial
port
are
available.
2.
If
all
interrupts
are
being
used
by
adapters,
remove
an
adapter
to
make
an
interrupt
available
to
the
serial
port,
or
force
other
adapters
to
share
an
interrupt.
3.
Make
sure
that
the
serial
port
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it
and
save
the
setting.
Chapter
2.
Diagnostics
23
Содержание IntelliStation A Pro 6217
Страница 1: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 8: ...vi IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 16: ...xiv IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 94: ...78 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 158: ...142 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 170: ...154 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 186: ...170 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 187: ......
Страница 188: ...Part Number 31R1994 Printed in USA 1P P N 31R1994...