DSA messages
Use this information to review the diagnostic error messages and solve many
errors.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest level of the UEFI code is installed. To download the latest
firmware for the compute node, go to http://www.ibm.com/support/fixcentral/.
The following table describes the messages that the diagnostic programs might
generate and suggested actions to correct the detected problems. Follow the
suggested actions in the order in which they are listed in the action column. In the
error codes,
x
can be any numeral or letter. However, if the three-digit number in
the central position of the code is 000, 195, or 197,
do not
replace a CRU. These
numbers appearing in the central position of the code have the following
meanings:
000
The compute node passed the test. Do not replace a CRU.
195
The Esc key was pressed to end the test. Do not replace a CRU.
197
This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU. Take the action that is indicated in the Action column, but
do not replace a CRU
. See the description for
Warning
messages” on page 66 for more information.
Microprocessor test
Use this information to diagnose and solve microprocessor test errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 5, “Parts listing, Types 7917 and 2584,” on page 51 to determine
which are components are consumable parts and which components are
customer replaceable units (CRUs).
v
If an action step is preceded by “(Trained service technician only),” that step
must be performed only by a trained service technician.
089-000-xxx
Explanation:
Passed the CPU stress test
User response:
Information only; no action is required.
089-801-xxx
Explanation:
Aborted due to an internal program error.
User response:
Complete the following steps:
1.
If the compute node has stopped responding, turn off and restart the compute node. See “Turning off the
compute node” on page 15 and “Turning on the compute node” on page 13.
2.
Make sure that the DSA code is up-to-date, upgrade if necessary; then, run the test again. The latest code can be
found at http://www.ibm.com/support/entry/portal/docdisplay?lndocid=SERV-DSA.
3.
Make sure that the system firmware level is up-to-date, upgrade if necessary; then, run the test again. The
installed firmware level can be found in the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/fixcentral/.
4.
If the compute node has stopped responding, turn off and restart the compute node; then, run the test again. See
“Turning off the compute node” on page 15 and “Turning on the compute node” on page 13.
5.
(Trained service technician only) If the component failure remains, see Chapter 7, “Installing, removing, and
replacing compute node components,” on page 487 to replace the failed component.
089-000-xxx • 089-801-xxx
Chapter 6. Troubleshooting
457
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...