80070617-2c01ffff
Sensor Mezz Exp 1 Fault has transitioned to non-recoverable.
Explanation:
A problem has been detected in the I/O expansion adapter in I/O expansion connector 1. The adapter
is unable to initialize.
May also be shown as 800706172c01ffff or 0x800706172c01ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Remove the I/O expansion adapter in I/O expansion connector 1.
2.
Try to power on the chassis.
v
If the chassis successfully powers on, complete the following steps:
a.
Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b.
Inspect the previously installed components for physical damage.
v
If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070617-2c02ffff
Sensor Mezz Exp 2 Fault has transitioned to non-recoverable.
Explanation:
A problem was detected in the I/O expansion adapter in I/O expansion connector 2. The adapter is
unable to initialize.
May also be shown as 800706172c02ffff or 0x800706172c02ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Remove the I/O expansion adapter in I/O expansion connector 2.
2.
Try to power on the chassis.
v
If the chassis successfully powers on, complete the following steps:
a.
Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b.
Inspect the previously installed components for physical damage.
v
If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070617-2c03ffff
Sensor Mezz Exp 3 Fault has transitioned to non-recoverable.
Explanation:
A problem was detected in the I/O expansion adapter in I/O expansion connector 3. The adapter is
unable to initialize.
May also be shown as 800706172c03ffff or 0x800706172c03ffff
Severity:
Error
80070617-2c01ffff • 80070617-2c03ffff
126
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......