80070601-2c04ffff
Sensor Mezz Exp 4 temp has transitioned to non-recoverable.
Explanation:
The temperature of the I/O expansion adapter in I/O expansion connector 4 has exceeded its specified
threshold. The compute node has attempted a soft shutdown.
May also be shown as 800706012c04ffff or 0x800706012c04ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps until the problem is solved:
1.
Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
4.
If there are no other thermal issues, replace the I/O expansion adapter.
8007060f-2201ffff
Sensor BOFM Config Err has transitioned to non-recoverable.
Explanation:
BOFM Config Error has been detected.
May also be shown as 8007060f2201ffff or 0x8007060f2201ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
80070614-2201ffff
Sensor TPM Phy Pres Set has transitioned to non-recoverable.
Explanation:
Trusted Platform Module (TPM) initialization error.
May also be shown as 800706142201ffff or 0x800706142201ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
80070601-2c04ffff • 80070614-2201ffff
Chapter 6. Troubleshooting
125
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...