806f010c-2581ffff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation:
This message is for the use case when an implementation has detected a Memory uncorrectable error.
All DIMMs. One of the DIMMs.
May also be shown as 806f010c2581ffff or 0x806f010c2581ffff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0138
SNMP Trap ID:
41
Automatically notify Support:
Yes
User response:
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
806f010d-0400ffff
The Drive Drive 0 has been disabled due to a detected fault.
Explanation:
The hard disk drive controller has detected a fault in hard disk drive 0. Hard disk drive 0 is now
defunct.
May also be shown as 806f010d0400ffff or 0x806f010d0400ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0164
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
Complete the following steps until the problem is solved:
1.
Check the Support Portal for service bulletins and RETAIN tips related to your drive.
2.
Check the Support Portal for firmware updates related to your drive.
3.
Replace the drive.
4.
Check for any other RAID-related errors.
806f010d-0401ffff
The Drive Drive 1 has been disabled due to a detected fault.
Explanation:
The hard disk drive controller has detected a fault in hard disk drive 1. Hard disk drive 1 is now
defunct.
May also be shown as 806f010d0401ffff or 0x806f010d0401ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0164
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
Complete the following steps until the problem is solved:
1.
Check the Support Portal for service bulletins and RETAIN tips related to your drive.
806f010c-2581ffff • 806f010d-0401ffff
Chapter 6. Troubleshooting
159
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...