v
Restore data from backup.
806f060d-0403ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 3 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0403ffff or 0x806f060d0403ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drives that are indicated by a lit status LED on the drive.
v
Recreate the array.
v
Restore data from backup.
806f060d-0404ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 4 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0404ffff or 0x806f060d0404ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Replace the hard disk drives that are indicated by a lit status LED on the drive.
v
Recreate the array.
v
Restore data from backup.
806f060d-0405ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 5 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0405ffff or 0x806f060d0405ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
806f060d-0403ffff • 806f060d-0405ffff
224
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...