Working with Internal Disk Drives
b. If the Power/Fault light is amber, remove the drive from the
unit and wait 10 seconds; then, reinstall the drive. If your
SCSI adapter is the IBM ServeRAID, go to the ServeRAID
User's Guide for additional information and procedures on
changing the state of the drive from the current Default
state to any other state (for example, HSP, RDY, rebuild
drive to ONL, and so on). The amber LED should go off
within 10 seconds of the drive state change (to something
other than DDD).
If your SCSI adapter is the IBM ServeRAID II, in some cases
the drive will automatically reset to either a hot spare (HSP)
or be rebuilt (ONL). See the ServeRAID II User's Guide for
additional information. If the state change in the ServeRAID
II configuration does not change automatically (amber LED
does not go off), then refer to the ServeRAID II User's Guide
for directions on how to perform a manual drive state
change. The amber LED should go off within 10 seconds of
a drive state change (to something other than DDD).
If the state change in the RAID configuration does not
change automatically, refer to your RAID Controller User's
Guide for directions on how to perform a drive state change.
c. Configure the drives using the appropriate disk array
software.
44
IBM Netfinity EXP15 Installation and User's Handbook
Содержание EXP15
Страница 1: ...IBM Netfinity EXP15 Installation and User s Handbook...
Страница 2: ......
Страница 3: ...IBM Netfinity EXP15 Installation and User s Handbook IBM...
Страница 8: ...vi IBM Netfinity EXP15 Installation and User s Handbook...
Страница 13: ...Safety Information xi...
Страница 19: ...Safety Information xvii...
Страница 22: ...xx IBM Netfinity EXP15 Installation and User s Handbook...
Страница 26: ...Welcome and Thank You xxiv IBM Netfinity EXP15 Installation and User s Handbook...
Страница 118: ...92 IBM Netfinity EXP15 Installation and User s Handbook...
Страница 124: ...IBM Part Number 24L7940 Printed in U S A September 1998 24L794...