location of the status and activity indicators). These lights are used to show when
there is drive activity or, in some cases, when there is a problem with your hard
disk drive.
v
The drive must be a low voltage differential drive (LVD), and have a single
connector attached (SCA) connector.
v
The hard disk drive bays connect to a SCSI
backplane
. This backplane is the
printed circuit board behind the bay and is connected to J4 on the system board.
v
The backplane controls the SCSI IDs for the hard disk drives.
Preinstallation steps
Before you install a hard disk drive, review the following.
v
Inspect the drive tray for any signs of damage.
v
Ensure that the drive is installed properly in the tray.
v
To maintain proper system cooling, do not operate the server/workstation for
more than two minutes without either a drive or a filler panel installed in each
bay.
v
If your server/workstation has a ServeRAID adapter installed; refer to the
documentation provided with the ServeRAID adapter for information about
adding a drive.
v
Read the safety precautions listed in “Safety information” on page 147,
“Handling electrostatic discharge-sensitive devices” on page 150.
v
Check the instructions that come with the drive for more information about
installing the drive.
Installing or replacing a hard disk drive
Refer to the following illustration to install a hard disk drive:
Note:
The illustrations in this document might differ slightly from your hardware.
Slim filler
Filler panel
Hard disk drive
Drive tray
Drive tray handle
(in open position)
Attention:
v
When you handle electrostatic discharge (ESD) sensitive devices, take
precautions to avoid damage from static electricity. For details on handling these
devices, refer to “Handling electrostatic discharge-sensitive devices” on page 150.
1.
Review the information in “Before you begin” on page 45.
2.
Turn off the server/workstation and all attached devices, and disconnect all
external cables and power cords.
Installing options
83
Содержание 867413x - Eserver xSeries 330 8674
Страница 2: ......
Страница 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Страница 165: ...Related service information 157...
Страница 167: ...Related service information 159...
Страница 169: ...Related service information 161...
Страница 171: ...Related service information 163...
Страница 183: ...Related service information 175...
Страница 191: ......
Страница 192: ...Part Number 24P2923 1P P N 24P2923...