3.
The DIMM error LEDs, processor error LEDs, and VRM error LEDs turn off
when the system is powered down.
Diagnostic Panel LED
FRU/Action
All LEDs off
(Check System Error
Log for error condition, then clear
System Error Log when the
problem is found.)
1.
System Error Log is 75% full; clear the log.
2.
PFA alert; check error log for failure; clear PFA alert; remove AC power for
at least 20 seconds, reconnect, then power up system.
3.
Run Information Panel diagnostics.
CPU LED on
(The LED next to the
failing CPU should be on.)
1.
Processor 1 or 2.
2.
System Board.
VRM LED on
1.
System Board
DASD LED on
(The LED located
next to the drive bay that the
failing drive is installed in will be
turned on.)
1.
Failing drive.
2.
Be sure the fans are operating correctly and the air flow is good.
3.
SCSI Backplane.
FAN LED on
1.
Check individual fan LEDs.
2.
Replace respective fan.
3.
System Board.
MEM LED on
(The LED next to
the failing DIMM is on.)
1.
DIMM.
2.
Failing DIMM in slot J1-J4.
3.
System Board
PCI LED on
1.
Remove PCI adapters from slots 1-2.
2.
System Board.
PS LED on
1.
Power Supply
2.
System Board
TEMP LED on
(look at test cases)
1.
Ambient temperature must be within normal operating specifications.
See “Features and specifications” on page 4.
2.
Ensure fans are operating correctly.
3.
Examine System Error Log.
a.
System over recommended temperature
b.
Power switch assembly
c.
DASD over recommended temperature
1)
Overheating hard drive
2)
DASD Backplane
3)
System Board
d.
System over recommended temperature for CPU X (where X is CPU
number,) (CPU LED also on)
1)
CPU X
2)
System Board
e.
System Board over recommended temperature
1)
System Board.
Diagnostic error codes
Note:
In the following error codes, if
XXX
is
000
,
195
, or
197
do not
replace a
FRU. The description for these error codes are:
122
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Содержание 867413x - Eserver xSeries 330 8674
Страница 2: ......
Страница 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Страница 165: ...Related service information 157...
Страница 167: ...Related service information 159...
Страница 169: ...Related service information 161...
Страница 171: ...Related service information 163...
Страница 183: ...Related service information 175...
Страница 191: ......
Страница 192: ...Part Number 24P2923 1P P N 24P2923...