Removing the cover
The following information describes how to remove the cover.
Cover release
lever
Screws
Complete the following steps to remove the cover from the server/workstation:
1.
Review the information in “Before you begin” on page 45.
2.
Turn off the server/workstation and all attached devices and disconnect all
external cables and power cords.
3.
Remove the server/workstation from the rack (see “Rack installation” on
page 46).
4.
Remove the two screws from the rear of the server/workstation.
5.
Pull out on the cover release lever at the back of the server/workstation, to
release the cover.
6.
Slide the cover back, then up and off the server/workstation.
Attention:
For proper cooling and airflow, replace the cover before turning
on the server/workstation. Operating the server/workstation for extended
periods of time (over 30 minutes) with the cover removed might damage
server/workstation components.
7.
Remove the clear shield that covers the inside of the server/workstation.
Note:
It is not necessary to remove the shield when you are installing memory
modules or installing an adapter in the PCI slots.
48
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Содержание 867413x - Eserver xSeries 330 8674
Страница 2: ......
Страница 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Страница 165: ...Related service information 157...
Страница 167: ...Related service information 159...
Страница 169: ...Related service information 161...
Страница 171: ...Related service information 163...
Страница 183: ...Related service information 175...
Страница 191: ......
Страница 192: ...Part Number 24P2923 1P P N 24P2923...