Table 5. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet controller (continued)
Error code (hex)
Description
0x02
Explanation:
Bad node address (multicast address).
Action:
Make sure the locally administered
address is valid, if one is specified. The address can not be a multicast address.
0x03
Explanation:
Failed self-test.
Action:
Make sure a cable is attached to the Ethernet connector. If
the problem persists, call for service.
0x0D
Explanation:
Could not allocate enough memory for transmit queues.
Action:
1.
From the Windows NT desktop, select
Start -> Control Panel -> Networks -> Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the resource values that apply to the transmit queue.
0x0E
Explanation:
Could not allocate enough memory for receive queue.
Action:
1.
From the Windows NT desktop, selec
t Start -> Control Panel -> Networks -> Adapter
s.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the resource values that apply to the receive queue.
0x0F
Explanation:
Could not allocate enough memory for other structures.
Action:
1.
From the Windows NT desktop, select
Start -> Control Panel -> Networks -> Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the value for the resource named in the message.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the Configuration/Setup
utility, make sure that Ethernet is enabled.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the required ID.
Action:
Using the Configuration/Setup utility, make sure that Ethernet is enabled.
0x13
Explanation:
Did not find any Ethernet controllers that matched the required subven/subdev.
Action:
Using the Configuration/Setup utility, make sure that Ethernet is enabled.
0x16
Explanation:
Single adapter found but multiple instances tried to load.
Action:
Using the
Configuration/Setup utility, make sure that Ethernet is enabled, and that the slot containing the
IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled.
0x17
Explanation:
Slot parameter not specified in the registry.
Action:
Remove the adapter driver and
reinstall it. If the problem persists, call for service.
All other
4-character
hexadecimal
codes
Action:
Call for service.
Ethernet teaming messages:
Table 6. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller
Event ID
Type
Description
01
Error
Explanation:
Team Name and physical adapter name are the same. This
is an invalid configuration.
Action:
Reconfigure the adapter team by
double-clicking the PROSet icon in the control panel.
02
Error
Explanation:
Unable to allocate required resources.
Action:
Free some
memory resources and restart.
03
Error
Explanation:
Unable to read required registry parameters.
Action:
Reconfigure the adapter team by double-clicking the PROSet icon in the
control panel.
Diagnostics
21
Содержание 867413x - Eserver xSeries 330 8674
Страница 2: ......
Страница 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Страница 165: ...Related service information 157...
Страница 167: ...Related service information 159...
Страница 169: ...Related service information 161...
Страница 171: ...Related service information 163...
Страница 183: ...Related service information 175...
Страница 191: ......
Страница 192: ...Part Number 24P2923 1P P N 24P2923...