3.
Remove the filler panel or defective hard drive from one of the hard disk drive
bays.
4.
Install the new hard disk drive in the drive bay:
a.
Ensure the tray handle is open (that is, perpendicular to the drive).
b.
Align the rails on the drive assembly with the guide rails in the drive bay.
c.
Gently push the drive assembly into the bay until the drive connects to the
backplane.
d.
Push the tray handle toward the closed position until it locks the drive in
place.
5.
Reconnect the external cables and power cords; then, turn on the
server/workstation.
6.
Check the hard disk drive status indicators to verify that the hard disk drives
are operating properly. (See “Server controls and indicators” on page 6 for the
location of the status indicators.)
v
When the green light flashes rapidly (three flashes per second), the controller
is identifying the drive.
Replacing a hard disk drive is done in the same manner as installing a new hard
disk drive.
Memory
Adding memory to the server/workstation is an easy way to improve system
performance. You can increase the amount of memory in the server/workstation
by installing options called
memory-module kits
. Each kit contains one
industry-standard, dual-inline memory module (DIMM). Your server/workstation
uses a noninterleaved memory configuration, which allows you to add, remove, or
replace one DIMM at a time. In an interleaved system you would have to add,
remove, or replace memory in sets.
The server/workstation comes with a dual inline memory module (DIMM)
installed on the system board in DIMM slot 1.
Note:
Install additional DIMMs in the following order: DIMM connector 2, then 3,
then 4. (See the following illustration for memory connector locations.)
Connector 1
Connector 2
Connector 3
Connector 4
84
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Содержание 867413x - Eserver xSeries 330 8674
Страница 2: ......
Страница 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Страница 165: ...Related service information 157...
Страница 167: ...Related service information 159...
Страница 169: ...Related service information 161...
Страница 171: ...Related service information 163...
Страница 183: ...Related service information 175...
Страница 191: ......
Страница 192: ...Part Number 24P2923 1P P N 24P2923...