Unblocking logical drives:
Whenever the
ServeRAID controller performs a rebuild operation on an
array, the data stored in any RAID level 1 and RAID level 5
logical drives in the array is reconstructed. However, the
data stored in RAID level 0 logical drives in that array
cannot be reconstructed. The data in the RAID level 0
logical drives is blocked when the ServeRAID controller
detects that the array is valid, but the data might be
damaged.
After the rebuild process completes, you can unblock the
RAID level 0 logical drives; this redefines their state as
OKY and allows access to them once again. But
remember, the RAID level 0 logical drive might contain
damaged data. You must re-create, install, or restore the
data for the RAID level 0 logical drive from the most recent
backup disk or tape.
To unblock a blocked drive:
1. Select the logical drive that is blocked from the Main
Menu of the Administration and Monitoring utility
program.
A screen similar to the following appears.
Logical Drive Information
Logical Drive Number
1
Blocked
No
Part of Array
A
Part of Merge Group
1
Date Created
05/19/97
State
OKY
Size
100MB
RAID Level
0
Write Policy
WT
Read Ahead
On
Strip Unit Size
8 KB
Number of Chunks
3
Stripe Order
1,1 1,2 1,4
Unblock
Initialize
Synchronize
OK
2. Click on Unblock to unblock the drive.
3. You
must initialize all new logical drives before storing
data in them. See with “Initializing logical drives” on
page 36.
4. Restore the data to the drive from the most recent
backup disk or tape.
Logical drive migration administration:
The
logical drive migration (LDM) feature dynamically changes
the current logical drive structure. You can use this
feature to change the RAID level, increase the free space
in a disk array, or change the size of a logical drive.
To use the LDM feature, you must have two logical drives
available: one free (FRE) logical drive and one source
38
Netfinity Server HMM
Содержание 86604RU - Netfinity 5500 - 4RU
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...