v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
166-060-000
System Management: Failed. Unable to
communicate with the Remote Supervisor
Adapter II SlimLine. It may be busy. Run the
test again.
1. Update the firmware (BIOS, service processor,
and diagnostics; see “Updating the firmware” on
page 13).
2. Run the diagnostic test again.
3. Correct other error conditions (including failed
systems-management tests and items that are
logged in the Remote Supervisor Adapter II
SlimLine system-error log) and run the diagnostic
test again.
4. Disconnect all server and device power cords
from the server, wait 30 seconds, reconnect the
power cords, and run the diagnostic test again.
5. Reseat the Remote Supervisor Adapter II
SlimLine. See “Removing the Remote Supervisor
Adapter II SlimLine” on page 58 and “Replacing
the Remote Supervisor Adapter II SlimLine” on
page 58.
6. Replace the Remote Supervisor Adapter II
SlimLine. See “Removing the Remote Supervisor
Adapter II SlimLine” on page 58 and “Replacing
the Remote Supervisor Adapter II SlimLine” on
page 58.
166-070-000
System Management: Failed. Unable to
communicate with the Remote Supervisor
Adapter II SlimLine. It may be busy. Run the
test again.
1. Update the firmware (BIOS, service processor,
and diagnostics; see “Updating the firmware” on
page 13).
2. Run the diagnostic test again.
3. Correct other error conditions (including failed
systems-management tests and items that are
logged in the Remote Supervisor Adapter II
SlimLine system-error log) and run the diagnostic
test again.
4. Disconnect all server and device power cords
from the server, wait 30 seconds, reconnect the
power cords, and run the diagnostic test again.
5. Reseat the Remote Supervisor Adapter II
SlimLine. See “Removing the Remote Supervisor
Adapter II SlimLine” on page 58 and “Replacing
the Remote Supervisor Adapter II SlimLine” on
page 58.
6. Replace the Remote Supervisor Adapter II
SlimLine. See “Removing the Remote Supervisor
Adapter II SlimLine” on page 58 and “Replacing
the Remote Supervisor Adapter II SlimLine” on
page 58.
Chapter 5. Diagnostics
127
Содержание 7163
Страница 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 209: ......
Страница 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...