v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1800
Unavailable PCI hardware interrupt.
1. Run the Configuration/Setup Utility program and
adjust the adapter settings. See “Starting the
Configuration/Setup Utility program” on page 14
2. Remove each adapter one at a time, restarting
the server each time, until the problem is isolated.
1801
An adapter has requested memory
resources that are not available
1. Rearrange the order of the adapters in the PCI
slots, if possible.
2. Run the Configuration/Setup Utility program,
select
Startup Options
, and change the startup
sequence. See “Starting the Configuration/Setup
Utility program” on page 14
3. Run the Configuration/Setup Utility program and
disable other resources, if possible. See “Starting
the Configuration/Setup Utility program” on page
14
a. Select
Startup Options
to disable the
onboard Ethernet controller option ROM.
b. Select
Advanced Setup
to disable the option
ROM of adapters in the PCI slots.
c. Select
Devices and I/O Ports
to disable any
of the integrated devices.
4. If the problem remains, replace the following
components one at a time, in the order shown,
restarting the server each time:
a. Each adapter
b. (Trained service technician only) I/O board.
See “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board
assembly” on page 69.
90
IBM System x3755 Type 8877 and 7163: Problem Determination and Service Guide
Содержание 7163
Страница 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Страница 209: ......
Страница 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...