SCSI
Utilities
SCSI
Utilities
allow
you
to
set
delay
times
for
the
SCSI
hard
disk
spin-up
and
to
set
SCSI
IDs
for
SCSI
controllers
installed
in
the
system.
SCSI
Utilities
1.
Harddrive
Spin
Up
Delay
2.
Change
SCSI
Id
.--------.
|
X=Exit
|
`--------’
===>
Using
the
Harddrive
Spin
Up
Delay
option
allows
you
to
change
the
spin
up
delay
time
for
SCSI
hard
disk
drives
attached
to
your
system.
Spin
up
delay
values
can
be
entered
manually,
or
you
can
use
a
default
setting
(two
seconds).
All
values
are
measured
in
seconds.
Attention:
Setting
the
value
lower
than
the
default
can
prevent
successful
booting
because
the
system
power
handling
capabilities
might
be
exceeded.
If
the
system
no
longer
boots
after
setting
this
value,
access
this
utility
again
and
increase
the
value.
It
is
also
possible
that
adding
disk
drives
can
cause
similar
symptoms.
Changing
this
value
changes
the
surge
current
requirements
on
the
system.
As
you
increase
the
value,
the
surge
current
requirements
on
the
system
are
decreased.
Select
Console
Select
this
option
to
define
which
display
is
used
by
the
system
for
system
management.
If
no
console
is
selected,
the
console
defaults
to
serial
port
1.
Selecting
this
option
causes
a
screen
similar
to
the
one
that
follows
to
display
on
each
console
that
can
be
used
as
a
firmware
console.
Follow
the
instructions
on
the
screen
to
select
a
particular
console.
Note:
The
firmware
console
is
independent
from
the
AIX
console.
Press
0
to
select
this
console
as
the
active
console
Chapter
8.
Using
System
Management
Services
419
Содержание 6H0
Страница 2: ......
Страница 12: ...x Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 18: ...xvi Service Guide ...
Страница 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Страница 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Страница 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Страница 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Страница 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Страница 88: ...68 Service Guide ...
Страница 94: ...74 Service Guide ...
Страница 182: ...162 Service Guide ...
Страница 444: ...424 Service Guide ...
Страница 468: ...Replacement Replace in reverse order 448 Service Guide ...
Страница 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Страница 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Страница 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Страница 495: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 Chapter 10 Parts Information 475 ...
Страница 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Страница 510: ...490 Service Guide ...
Страница 522: ...502 Service Guide ...
Страница 546: ...526 Service Guide ...
Страница 552: ...532 Service Guide ...
Страница 559: ......
Страница 560: ... Printed in USA April 2002 SA38 0566 03 ...
Страница 561: ...Spine information RS 6000 Enterprise Server Model H80 Eserver pSeries 660 Models 6H0 and 6H1 Service Guide SA38 0566 03 ...