Table
6.
Service
Processor
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406B
00B7
Wire
test
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406B
0100
Wire
test
detected
memory
riser
card
fault
Memory
riser
card
Location:
U1.1-P1-M2
406B
0101
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.15
406B
0102
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
406B
0103
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.16
406B
0104
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.2
406B
010D
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
x4
406B
0111
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.13
406B
0112
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.3
406B
0113
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.14
406B
0114
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.4
406B
011D
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.3
x4
406B
0121
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.11
406B
0122
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.5
406B
0123
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.12
406B
0124
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.6
406B
012D
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.5
x4
406B
0131
Wire
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.9
244
Service
Guide
Содержание 6H0
Страница 2: ......
Страница 12: ...x Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 18: ...xvi Service Guide ...
Страница 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Страница 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Страница 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Страница 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Страница 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Страница 88: ...68 Service Guide ...
Страница 94: ...74 Service Guide ...
Страница 182: ...162 Service Guide ...
Страница 444: ...424 Service Guide ...
Страница 468: ...Replacement Replace in reverse order 448 Service Guide ...
Страница 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Страница 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Страница 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Страница 495: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 Chapter 10 Parts Information 475 ...
Страница 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Страница 510: ...490 Service Guide ...
Страница 522: ...502 Service Guide ...
Страница 546: ...526 Service Guide ...
Страница 552: ...532 Service Guide ...
Страница 559: ......
Страница 560: ... Printed in USA April 2002 SA38 0566 03 ...
Страница 561: ...Spine information RS 6000 Enterprise Server Model H80 Eserver pSeries 660 Models 6H0 and 6H1 Service Guide SA38 0566 03 ...