Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E5xy
(E511
-
E5FF)
Where
x
is
not
equal
to
0,
and
y
is
not
equal
to
0.
Configure
remote
I/O
subsystem
components
The
E5xy
(E511
to
E5FF)
codes
are
reserved
for
activities
relating
to
configuration
or
testing
of
the
I/O
subsystem,
or
remote
I/O
subsystem.
A
hang
at
one
of
these
codes
implies
that
a
severe
error
occurred
during
the
programming
of
I/O
subsystem
registers
or
when
interacting
with
adapters
plugged
into
the
system.
The
last
two
digits
in
the
checkpoint
can
be
used
to
help
isolate
the
location
of
the
I/O
activity
that
caused
the
problem.
“
x
”
indicates
the
I/O
drawer
number.
“
y
”
indicates
the
PCI
bus
occurrence.
If
y=_,
then
the
PCI
Bus
is:
Y
=
PCI
Bus
1
=
0
2
=
1
3
=
2
4
=
3
See
“AIX
and
Physical
Location
Code
Tables”
in
Chapter
1,
for
location
codes.
Using
the
information
above,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
E600
SSA
PCI
adapter
open
firmware
has
run
successfully.
Replace
the
adapter.
See
“Checkpoint
and
Error
Code
Index”
on
page
165
for
location
code
information
related
to
this
error.
E601
SSA
PCI
adapter
BIST
has
started
but
failed
to
complete
after
four
seconds.
Replace
the
adapter.
See
“Checkpoint
and
Error
Code
Index”
on
page
165
for
location
code
information
related
to
this
error.
E602
SSA
PCI
adapter
open
firmware
has
started.
Replace
the
adapter.
See
“Checkpoint
and
Error
Code
Index”
on
page
165
for
location
code
information
related
to
this
error.
E603
SSA
PCI
adapter
BIST
has
completed
with
an
error.
Replace
the
adapter.
See
“Checkpoint
and
Error
Code
Index”
on
page
165
for
location
code
information
related
to
this
error.
156
Service
Guide
Содержание 6H0
Страница 2: ......
Страница 12: ...x Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 18: ...xvi Service Guide ...
Страница 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Страница 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Страница 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Страница 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Страница 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Страница 88: ...68 Service Guide ...
Страница 94: ...74 Service Guide ...
Страница 182: ...162 Service Guide ...
Страница 444: ...424 Service Guide ...
Страница 468: ...Replacement Replace in reverse order 448 Service Guide ...
Страница 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Страница 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Страница 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Страница 495: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 Chapter 10 Parts Information 475 ...
Страница 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Страница 510: ...490 Service Guide ...
Страница 522: ...502 Service Guide ...
Страница 546: ...526 Service Guide ...
Страница 552: ...532 Service Guide ...
Страница 559: ......
Страница 560: ... Printed in USA April 2002 SA38 0566 03 ...
Страница 561: ...Spine information RS 6000 Enterprise Server Model H80 Eserver pSeries 660 Models 6H0 and 6H1 Service Guide SA38 0566 03 ...