Table
6.
Service
Processor
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406C
00A6
IPL
test
detected
no
usable
memory
1.
Ensure
that
memory
DIMMs
and
cards
are
properly
installed.
2.
Go
to
service
processor
memory
configuration/deconfiguration
menu
to
verify
memory
DIMMs
state.
See
″
Memory
Configuration/Deconfiguration
Menu
″
on
page
384
for
more
information.
3.
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
406C
00A7
IPL
test
detected
hardware
problem
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
406C
00B0
IPL
test
detected
bus
controller
lock-unlock
failure
RIO
adapter
Location:
U0.1-P1.1
406C
00B1
IPL
test
detected
bus
controller
failure
RIO
adapter
Location:
U0.1-P1.1
406C
00B7
IPL
MOPS
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406C
0100
IPL
test
detected
memory
riser
card
fault
Memory
riser
card
Location:
U1.1-P1-M2
406C
0101
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.15
406C
0102
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
406C
0103
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.16
406C
0104
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.2
406C
010D
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
x4
406C
0111
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.13
406C
0112
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.3
406C
0113
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.14
406C
0114
IPL
test
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.4
Chapter
5.
Error
Code
to
FRU
Index
249
Содержание 6H0
Страница 2: ......
Страница 12: ...x Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 18: ...xvi Service Guide ...
Страница 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Страница 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Страница 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Страница 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Страница 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Страница 88: ...68 Service Guide ...
Страница 94: ...74 Service Guide ...
Страница 182: ...162 Service Guide ...
Страница 444: ...424 Service Guide ...
Страница 468: ...Replacement Replace in reverse order 448 Service Guide ...
Страница 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Страница 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Страница 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Страница 495: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 Chapter 10 Parts Information 475 ...
Страница 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Страница 510: ...490 Service Guide ...
Страница 522: ...502 Service Guide ...
Страница 546: ...526 Service Guide ...
Страница 552: ...532 Service Guide ...
Страница 559: ......
Страница 560: ... Printed in USA April 2002 SA38 0566 03 ...
Страница 561: ...Spine information RS 6000 Enterprise Server Model H80 Eserver pSeries 660 Models 6H0 and 6H1 Service Guide SA38 0566 03 ...