v
Reprogram
Flash
EPROM
Menu
This
option
updates
the
system
EPROMs.
After
entering
Y
to
indicate
that
you
want
to
continue,
you
are
prompted
to
enter
the
update
diskettes.
Follow
the
instructions
on
the
screen.
When
the
update
is
complete,
the
service
processor
reboots.
All
system
EPROMs
that
can
be
reprogrammed
are
updated
at
the
same
time.
They
are
as
follows:
–
System
power
control
network
programming
–
Service
processor
programming
–
System
firmware
–
Run-time
abstraction
services
v
Serial
Port
Snoop
Setup
Menu
This
menu
can
be
used
to
set
up
serial
port
snooping,
in
which
the
user
can
configure
serial
port
1
as
a
″
catch-all
″
reset
device.
From
the
service
processor
main
menu,
select
option
1,
Service
Processor
Setup
Menu,
then
select
option
8
(Serial
Port
Snoop
Setup
Menu).
SERIAL
PORT
SNOOP
SETUP
MENU
1.
System
reset
string:
Currently
Unassigned
2.
Snoop
Serial
Port:
Currently
Unassigned
98.
Return
to
Previous
Menu
1>
Use
the
system
reset
string
option
to
enter
the
system
reset
string,
which
resets
the
machine
when
it
is
detected
on
the
main
console
on
serial
port
1.
Use
the
snoop
serial
port
option
to
select
the
serial
port
to
snoop.
Note:
Only
serial
port
1
is
supported.
After
serial
port
snooping
is
correctly
configured,
at
any
point
after
the
system
unit
is
booted
to
AIX,
whenever
the
reset
string
is
typed
on
the
main
console,
the
system
unit
reboots.
Pressing
Enter
after
the
reset
string
is
not
required,
so
make
sure
that
the
string
is
not
common
or
trivial.
A
mixed-case
string
is
recommended.
Chapter
7.
Using
the
Service
Processor
377
Содержание 6H0
Страница 2: ......
Страница 12: ...x Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 18: ...xvi Service Guide ...
Страница 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Страница 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Страница 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Страница 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Страница 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Страница 88: ...68 Service Guide ...
Страница 94: ...74 Service Guide ...
Страница 182: ...162 Service Guide ...
Страница 444: ...424 Service Guide ...
Страница 468: ...Replacement Replace in reverse order 448 Service Guide ...
Страница 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Страница 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Страница 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Страница 495: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 Chapter 10 Parts Information 475 ...
Страница 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Страница 510: ...490 Service Guide ...
Страница 522: ...502 Service Guide ...
Страница 546: ...526 Service Guide ...
Страница 552: ...532 Service Guide ...
Страница 559: ......
Страница 560: ... Printed in USA April 2002 SA38 0566 03 ...
Страница 561: ...Spine information RS 6000 Enterprise Server Model H80 Eserver pSeries 660 Models 6H0 and 6H1 Service Guide SA38 0566 03 ...