Installation Requirements > Key Features
Revision: 180906
Veo16i User Manual
Page | 7
Installation Requirements
To function properly and to its full potential, i3 DVR must be in a clean dust free room and a well-
ventilated area with consistent temperatures within the
acceptable range of 20-25° Celsius
. The
acceptable temperature range must be maintained for the stability of the i3 DVR Server.
Operating Relative Humidity in the server room should fall within the
acceptable range of 20% to 80%
(non-condensing)
.
An Uninterrupted Power Supply (1000 VA) with a constant power of 118 to 120 AC
must be used
with each i3 DVR Server. If the installation environment does not meet the conditions above, there is a
risk of system malfunction.
i3 International will only warranty its products if the installation environment meets the conditions above.
Should the environmental conditions be not met, the i3 DVR Server warranty will be voided.
When selecting a storage location for the system, be sure to avoid:
•
excessive heat, such as direct sunlight or heating appliances
•
moisture, dust, and smoke
•
magnetic fields or electrical waves
•
temperatures below 5° Celsius or 41° Fahrenheit
•
any obstructions to system ventilation holes
Before installing this system, always ensure the:
•
power source is located within 3 feet or 1 meter of the UPS
•
power is switched off (**Do not plug the DVR unit in.)
•
system and its connecting cables have sufficient space
•
system is placed on an even surface
•
system is situated far from electronic equipment such as microwaves, radios, fridge
compressors, or any type of wireless equipment such as a telephones or cell phones)
•
system is at room temperature (18° - 25° Celsius or 64.4° - 77° Fahrenheit)
Restricted Access Location
This equipment is intended for installation in Restricted Access Location.
For instructions on how to monitor DVR fan and internal temperature failure events, refer to