System Setup > Event Settings
Revision: 180906
Veo16i User Manual
Page | 69
>
S.M.A.R.T. STATUS: Reads and displays the disk current S.M.A.R.T information.
- NORMAL: The hard disk is healthy and is being used.
- CHECK: Hard disk error was detected. The hard disk is not being used for recording. Check
the hard drive cable connection. If the status does not change to NORMAL, replace the hard
drive.
- ERROR: The hard disk has failed and is not being used. Check all cable connections. If the
status does not change to NORMAL, replace the hard drive.
>
S.M.A.R.T. CHECK INTERVAL: Set the S.M.A.R.T. check interval to 12 HOUR or 24 HOUR.
>
CHECK NOW: Manually initiate S.M.A.R.T. check
Click
APPLY
to save new configurations.
When done, click
CLOSE
or press [
EXIT
] on the remote control.
Event Settings
<SYSTEM SETUP> - <EVENT>
Configure system event response to Alarm In/Out activity.
Use mouse cursor or the navigation buttons on the remote control (
▲▼
◀▶
/ ENTER)
Alarm Out
<SYSTEM SETUP> - <EVENT> - <ALARM OUT>
For instructions on how to connect Alarm Out devices, refer to
Use mouse cursor or the navigation buttons on the remote control (
▲▼
◀▶
/ ENTER) to switch between
ALARM OUT
and
ON/OFF SCHEDULE
tabs.
>
NAME: Assign a custom name to Alarm Output.
>
OPERATION: Set to N/O (Normal Open) or N/C (Normal Close):
N/O
(Normally Open). Normally Open. Switches to Close when alarm occurs.
N/C
(Normal Close): Normally Close. Switches to Open when alarm occurs.