Performing maintenance
FAM 5
en(us)
63 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
5.
Screw the drain screw clockwise out of
the heater.
6.
Collect the escaping fluid in a suitable
container.
Fill the oil back into the tank or dispose
of it in an environmentally-friendly
manner.
7.
Screw the drain plug counterclockwise
into the filter bowl and tighten it firmly.
8.
Emptying the heater is now complete.