FAM Set-up and Connection
FAM 5
en(us)
37 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Connecting the inlet (IN)
NOTICE
Moving unsecured hoses / lances in the tank
The hoses/lances fall out of the tank
►
Attach the hoses/lances to the tank and secure them against falling
out.
NOTICE
Contamination in the medium too high
The FAM will be damaged
►
Do not prime directly at the bottom of the tank
►
Do not prime in the sump
►
Never prime without a built-in suction screen
►
Never suck in free water
The greatest contamination is found on the bottom of the tank.
All impurities like water or solid particles are deposited on the
bottom of the tank. Drain out the deposited, free water at the
bottom of the tank.
The suction pressure at the FAM inlet must be -0.2 bar.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Note that the cross-section of the connected hoses/piping, must be at least
as large as the cross-section of the inlet/outlet port sizes.
The shape of the tank connection should be set up in such a way that it will
always be lower than the level of the oil.