FAM Set-up and Connection
FAM 5
en(us)
35 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Notes on pipes and hoses
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
NOTICE
Non-permitted pressure at the inlet IN / outlet OUT
Failure malfunction
►
Determine the pressure to be anticipated at the inlet / outlet with the
prescribed values.
Note that the cross-section of the connected hoses/piping, must be at least
as large as the cross-section of the inlet/outlet port sizes.
In order to keep the pressure loss as low as possible, use few threaded
connections.
The pressure at the inlet/outlet depends on the height differential between
the suction connection on the FAM and the fluid surface in the tank
(aspiration height
P
(height)
) and the line losses (
P
(line)
).
If the FAM is above the fluid surface in the tank, determine the pressure as
follows:
P = 1 bar -
P
(height)
-
P
(line)
If the FAM is below the fluid surface in the tank, determine the pressure as
follows:
P = 1 bar +
P(height)
-
P
(line)
Determine the pressure loss
P
(height)
as follows:
P
(height)
[bar] = h [m] / 10.
h
stands here for the distance between the suction connection on the FAM
and the fluid surface in the tank and is given in meters.
Содержание FAM-5-M-2-A-05-R-H-B-Z-1
Страница 15: ...Safety information FAM 5 en us 15 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Knowledge about reuse ...
Страница 25: ...FAM Description FAM 5 en us 25 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 FAM system components ...
Страница 29: ...Hydraulic diagram FAM 5 en us 29 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Hydraulic diagram ...
Страница 98: ......
Страница 99: ......