Performing maintenance
FAM 5
en(us)
54 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Performing maintenance
WARNING
FAM in operation
Danger of bodily injury
►
Switch off the unit before any maintenance
The safety of all persons coming into contact with the FAM and the
availability of the unit for use are dependent on regular servicing and
maintenance.
Maintenance intervals
The inspection and maintenance works listed here are necessary conditions
for ensuring both long service life and error-free operation of the FAM.
In addition, you will find further information in the operating manuals
published by the manufacturers of the components which are supplied with
the FAM.
See page
24 hours /
daily
500 hours /
monthly
3000 hour
s /
every six months
6000 hour
s /
annually
FAM
Check the FAM for any leaks
(visual check).
-
X
Check the screwed fittings to see
that they have been properly
resecured.
-
X
Check the testing method /
Vacuum pressure gauge in the
vacuum column /
Differential pressure gauge on the
fluid filter
-
X
Check the fault signal lamps
X
Содержание FAM-5-M-2-A-05-R-H-B-Z-1
Страница 15: ...Safety information FAM 5 en us 15 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Knowledge about reuse ...
Страница 25: ...FAM Description FAM 5 en us 25 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 FAM system components ...
Страница 29: ...Hydraulic diagram FAM 5 en us 29 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Hydraulic diagram ...
Страница 98: ......
Страница 99: ......