Performing maintenance
FAM 5
en(us)
68 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Filling/Refilling vacuum pump oil
WARNING
Hot surfaces
Risk of burns
►
Keep distant from hot surfaces.
►
Allow the vacuum pump to cool down before
performing any work.
Proceed as follows to fill the vacuum pump:
1. Switch the unit off at the
main switch and unplug the
power connector.
Allow the vacuum pump to
cool down.
2. Remove the threaded
coupling (k) for the plug at
the level switch.
Remove the plug (I) for the
level switch in an upward
direction.