Troubleshooting
FAM 5
en(us)
51 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
the fluid filter.
See page 76 for details.
5.
Switch on the unit at the main switch and start the unit by
pressing the on switch.
-
>a.
The unit starts and runs
normally.
-> proceed to Step 100.
6.
-
>b.
The unit stops after 3 seconds
and the "Fault / Unit off" signal
lamp comes on.
-> proceed to Step 7.
7.
Check the oil level in the oil pan.
-
>a.
The float switch in the oil
collecting pan triggered due to
the oil.
-> proceed to Step 9.
8.
-
>b.
There is no oil/fluid in the oil
collecting pan.
-> proceed to Step 12.
9.
Look for and fix the leak immediately.
10.
Empty the oil collecting pan. See page 57.
-
>a.
The unit starts and runs
normally.
-> proceed to Step 100.
11. -
>b.
The unit does not start and the
"Fault / Unit off" signal lamp
comes on.
-> proceed to Step 12.
12.
Check the oil level in the vacuum pump. See page 66.
-
>a.
Oil level in the vacuum pump
outside the MIN / MAX
markings.
-> proceed to Step 14.
13.
-
>b.
Vacuum pump oil level OK.
Within the MIN / MAX mark.
-> proceed to Step 17.
14.
Fill the vacuum pump (see page 68 ) or drain the vacuum pump
oil slightly (see page 71).
15.
Start the unit by pressing the on switch.
-
>a.
The unit starts and runs
normally.
-> proceed to Step 100.
16.
-
>b.
The unit stops and the signal
lamp "Fault / Unit off" lights up.
-> proceed to Step 17.
17.
Check the vacuum column.
18.
-
>a.
If the level of the vacuum
column is above the mark that
has been applied.
-> proceed to Step 19.
Содержание FAM-5-M-2-A-05-R-H-B-Z-1
Страница 15: ...Safety information FAM 5 en us 15 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Knowledge about reuse ...
Страница 25: ...FAM Description FAM 5 en us 25 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 FAM system components ...
Страница 29: ...Hydraulic diagram FAM 5 en us 29 100 BEWA FAM5 3667663b en us 2012 12 12 doc 2012 12 12 Hydraulic diagram ...
Страница 98: ......
Страница 99: ......