Performing maintenance
FAM 5
en(us)
76 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Replacing the filter element on the fluid filter
If the signal lamp "Change fluid filter" lights up, replace the filter element as
described in the following:
1.
Switch off the FAM at the main switch
and close the shut-off valve at the inlet
and outlet in order to prevent the oil from
flowing back out of the tank.
Make sure that the unit cannot be
inadvertently switched back on during
maintenance work.
2.
Put a suitable container (1) in place to
catch exiting medium.
Depressurize the filter housing.
Carefully open the drain plug (2) on the
filter bowl and empty the filter housing
completely using the drain screw (SW
6mm) on the bottom of the filter housing.
The volume is ~ 2 liters.
After draining, replace the drain plug on
the filter bowl.
3.
Undo the housing clamp (1) on the filter
housing and then remove the housing by
moving it downwards (2).
Use an Allen wrench SW 6 mm (1).