11. Push the housing clamp (1) up around
the filter bowl over the bead on the filter
bowl / filter head.
Tighten the housing clamp with an Allen
wrench SW 6mm in a clockwise
direction.
The tightening torque is 5 Nm.
12. Check that the drain plug on the filter
bowl is secure.
13. The filter element change is now
complete.
Bleed the filter housing as described on
page 47.
After commissioning, check the filtration
unit for leaks.