ENS 3000 IO-Link
51
Stand 20.04.2020
HYDAC ELECTRONIC GMBH
Mat. Nr.: 669898
Process Data Formatting
Formatting for Process Data id=PI_PdIn
Subindex 1:
Subindex 2:
Subindex 3: * 0.1 + 0 cm Dec.1
Subindex 4:
Subindex 5:
Subindex 6: * 0.1 + 0 °C Dec.1
Events
Code
Type
Name
Description
36002 (0x8ca2) Error
User setup error
User setup is corrupt, device is running with factory settings
36016 (0x8cb0) Error
Primary value signal
error
Primary value update failed, device output is temporarily disabled
36017 (0x8cb1) Error
Secondary value
signal error
Secondary value update failed, device output is temporarily
disabled
36032 (0x8cc0) Warning
Primary value out of
range
Primary value is below or above its valid range and limited to the
corresponding lower or upper value
36033 (0x8cc1) Warning
Secondary value out
of range
Secondary value is below or above its valid range and limited to