38
ENS 3000 IO-Link
Stand: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Mat. Nr.: 669898
Standard Variable "Standard Command" index=2 id=V_SystemCommand
data type: 8-bit UInteger
allowed values: 128 = Device Reset, 129 = Application Reset, 130 = Restore Factory Settings,
160 = Reset Primary Min/Max, 161 = Reset Secondary Min/Max, 164 = Reset All
Min/Max
access rights: wo
modifies other variables
octet
0
bit offset
7 - 0
element bit
7 - 0
Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks
data type: 16-bit Record (subindex access not supported)
access rights: rw
subindex
bit offset
data type
name
description
1
0
Boolean
Parameter (write)
Access Lock
2
1
Boolean
Data Storage Lock
Datenhaltung (Subindex 2) ist aus
Kompatibilitätsgründen vorhanden und sollte immer
auf „False“ stehen, um unerwartetes Verhalten beim
Data Storage zwischen Master und Gerät zu
vermeiden.
3
2
Boolean
Local
Parameterization
Lock
4
3
Boolean
Local User Interface
Lock
SP = switch point RP = switch-back point FL = pressure window lower value FH = pressure window upper value
Variable "BDC1 Thresholds" index=60 id=V_Bdc1Thresholds
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables
excluded from data storage
subindex
bit
offset
data type
allowed
values
default
value
mod. other var.
name
description
1
16
16-bit Integer See 12.2
60
V_PrimaryValueS1
Setpoint SP1
Lower limit of
RP (FL) in cm
2
0
16-bit Integer See 12.2
68
V_PrimaryValueSp1
Setpoint SP2
Upper limit of
SP (FH) in cm
SP = switch point; RP = switch-back point; FL = level/temperature window lower value; FH = level/temperature window upper value
octet
0
1
2
3
bit offset
31 - 24
23 - 16
15 - 8
7 - 0
subindex
1
1
2
2
element bit
15 - 8
7 - 0
15 - 8
7 - 0
Variable "BDC1 Behavior" index=61 id=V_Bdc1Behavior
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables
excluded from data storage
For compatibility reasons only – it is
recommended to keep subindex 2 „false“ in
order to avoid any unwanted system
behavior if data storage is set via IO-Link
master.