ENS 3000 IO-Link
43
Stand 20.04.2020
HYDAC ELECTRONIC GMBH
Mat. Nr.: 669898
Variable "SP States" index=72 id=V_SpStates
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic
subindex
bit
offset
data type
allowed
values
default value
mod.
other var.
name
description
1
0
Boolean
false
Primary Value SP1
2
1
Boolean
false
Primary Value SP2
3
2
Boolean
false
Secondary Value SP1
4
3
Boolean
false
Secondary Value SP2
Octet 0
bit offset
7
6
5
4
3
2
1
0
subindex
/ / / / / /
/ / / / / /
/ / / / / /
/ / / / / /
4
3
2
1
Variable "Q1 Mapping" index=73 id=V_Q1Mapping
data type: 8-bit UInteger
allowed values: 0 = Primary Value SP1 (BDC1), 1 = Secondary Value SP1 (BDC3)
default value: 0
access rights: rw
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "Q2/QA Mapping" index=74 id=V_Q2QAMapping
data type: 24-bit Record (subindex access not supported)
access rights: rw
subindex
bit
offset
data type
allowed
values
default
value
mod.
other var.
name
description
1
16
8-bit UInteger
0 = Primary
Value SP2
(BDC2), 1 =
Secondary
Value SP2
(BDC4)
0
Output Source
2
8
8-bit UInteger
0 = digital
(Q2), 1 =
analog (QA)
0
Output Mode
3
0
8-bit UInteger
0 = 4..20mA,
1 = 0..10V
0
Analog Mode
octet
0
1
2
bit offset
23 - 16
15 - 8
7 - 0
subindex
1
2
3
element bit
7 - 0
7 - 0
7 - 0