ENS 3000 IO-Link
39
Stand 20.04.2020
HYDAC ELECTRONIC GMBH
Mat. Nr.: 669898
subindex
bit
offset
data type
allowed
values
default
value
mod. other var.
name
description
1
24
8-bit UInteger
0 = Default, 1
= Inverted
0
V_PrimaryValueSp1
Switch Point
Logic
NO/NC
2
16
8-bit UInteger
2 = Window,
3 = Two-Point
3
V_PrimaryValueSp1
Switch Point
Mode
3
0
16-bit
UInteger
0
V_PrimaryValueSp1
Switch Point
Hysteresis
octet
0
1
2
3
bit offset
31 - 24
23 - 16
15 - 8
7 - 0
subindex
1
2
3
3
element bit
7 - 0
7 - 0
15 - 8
7 - 0
Variable "BDC2 Thresholds" index=62 id=V_Bdc2Thresholds
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables
excluded from data storage
subindex
bit
offset
data type
allowed
values
default
value
mod. other var.
name
description
1
16
16-bit
Integer
See 12.2
94
V_PrimaryValueSp2 Setpoint SP1
Lower limit of RP
(FL) in cm
2
0
16-bit
Integer
See 12.2
102
V_PrimaryValueSp2 Setpoint SP2
Upper limit of SP
(FH) in cm
octet
0
1
2
3
bit offset
31 - 24
23 - 16
15 - 8
7 - 0
subindex
1
1
2
2
element bit
15 - 8
7 - 0
15 - 8
7 - 0
Variable "BDC2 Behavior" index=63 id=V_Bdc2Behavior
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables
excluded from data storage
subindex
bit
offset
data
type
allowed
values
default
value
mod. other var.
name
description
1
24
8-bit
UInteger
0 = Default, 1
= Inverted
0
V_PrimaryValueSp2
Switch Point
Logic
NO/NC
2
16
8-bit
UInteger
2 = Window, 3
= Two-Point
3
V_PrimaryValueSp2
Switch Point
Mode
3
0
16-bit
UInteger
0
V_PrimaryValueSp2
Switch Point
Hysteresis
octet
0
1
2
3
bit offset
31 - 24
23 - 16
15 - 8
7 - 0
subindex
1
2
3
3
element bit
7 - 0
7 - 0
15 - 8
7 - 0