44
ENS 3000 IO-Link
Stand: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Mat. Nr.: 669898
Variable "Display Mapping" index=75 id=V_DspMapping
data type: 8-bit UInteger
allowed values: 0 = Primary Value, 1 = Secondary Value
default value: 0
access rights: rw
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "Primary Value Display Unit" index=76 id=V_PrimaryValueDspUnit
data type: 8-bit UInteger
allowed values: 0 = cm, 1 = in
default value: 0
access rights: rw
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "Secondary Value Display Unit" index=77 id=V_SecondaryValueDspUnit
data type: 8-bit UInteger
allowed values: 0 = C, 1 = F
default value: 0
access rights: rw
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "Primary Value Range" index=80 id=V_PrimaryValueRange
data type: 72-bit Record (subindex access not supported)
access rights: ro
subindex
bit
offset
data type
allowed
values
default
value
mod.
other var.
name
description
1
56
16-bit Integer
See 12.2
0
Lower Value
2
40
16-bit Integer
See 12.2
170
Upper Value
3
32
8-bit Integer
1
Decimals
4
0
4-octet String
UTF-8
"cm"
Unit
octet
0
1
2
3
4
5
6
7
bit offset
71 - 64
63 - 56
55 - 48
47 - 40
39 - 32
31 - 24
23 - 16
15 - 8
subindex
1
1
2
2
3
4
4
4
element bit
15 - 8
7 - 0
15 - 8
7 - 0
7 - 0
octet
8
bit offset
7 - 0
subindex
4