68
Issue 3.3.2 / April, 2011
Program 05-04-IP : System Timing Parameters – 04
05-04-IP SYS PAR
4 1 0 0 0 0 0 0
IP = 01-08
System Default.
Item
Display
Pointer Data
Programming Data Description
Default
--------- ---------- -----------------------------------------------------------
-------------
01
0-9
System baud Rate Setting
4=9600
02
0-1
Dial 9 Flag
1=Enable
03
0-8
Action for Call Duration Limiting
0=Warning
04
0-1
12/24 Hours Clock
0=12 Hours
05
0-9
SLT Hookflash Answer Delay
0=None
06
0-4
Speed Dialling Distribution
0=100
Sets
07
0-1
Single Digit Intercom
0=Disable
08
0-4
Message Waiting Method - Analogue Phones
0=90v DC
Description:
01. System Baud Rate Setting:
This parameter sets the system Baud rate setting for SMDR and CTI applications. The baud rate
settings between 1200 and 9600 are the settings that should be used. DO NOT USE 19200 as it
contains an ISDN test procedure that will cause conflict with Call Accounting. 115200 is for G1E monitor
program and software upgrade for G1E only. G1E+ software upgrade is done at 56000. There is no
need to change settings in this mode to upgrade software. G1E Monitor must be enabled in mode 05-24.
0=1200
1=2400
2=3600
(SM5)
3=7200
4=9600
5=19200 6=38400
7=57600
8
=
115200
02. Dial 9 Flag:
This parameter sets if a station can access an outgoing line by dialling 9. If this parameter is disabled
the station can still access an outgoing line by pressing a line key.
0 = Can not access dial 9 feature
1 = Can access dial 9 feature
03. Action for Call Duration Limiting:
This parameter decides what action will be taken if a station has limit call duration enabled in Mode 40-
nnnn-03. Settings 0 to 3 are for outgoing calls only. The outside party will also hear the warning tone.
0 & 5 = Continuous Warning Tone after Timeout.
1 & 6 = 1 second Warning Tone for each cycle of Limit Call Duration
2 & 7 = At 10 seconds before Timeout, 1 second Warning Tone,
At 5 seconds before timeout, continuous Warning Tone,
At timeout the line is released.
3 & 8 = At 1 minute before timeout, 1 second warning tone,
At 30 seconds before timeout, continuous warning tone
At timeout the line is released.
Related System Programming Mode: 05-04-03, 40-st-03
04. 12/24 Hours Clock:
0 = 12 Hours Clock
1 = 24 Hours Clock
Содержание G1E
Страница 16: ...Issue 3 3 2 April 2011 ...
Страница 26: ......
Страница 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Страница 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Страница 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Страница 74: ...58 Issue 3 3 2 April 2011 ...
Страница 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Страница 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Страница 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Страница 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Страница 127: ...G1E Programming Manual 111 ...
Страница 169: ...G1E Programming Manual 153 ...
Страница 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Страница 218: ......