Program 25 : Reset Data to System Default
25 - Reset Data
0 - 9 Default
General:
This program resets all data to System Default. All new systems must be reset to default before any
programming in case corruption has been caused during handling or shipping. It will also be necessary to reset
to default after a software upgrade is installed. When using item 3 or 4 these must be done AFTER the system
reset is performed.
Description:
1 = System data will be reset to system default except System Speed Dial Programming.
2 = The system data will be totally reset to system default.
WARNING
: All user-defined data will be lost.
3 = For all Stations set
44-st-02=1
(Hold Feature restricted)
44-st-03=1
(Call Split Feature restricted)
This feature is for Hotel/Motel operation. After setting this Mode it is necessary to reprogram the
Console and any Administration phones in Mode 44-st-02 to allow them to place calls on hold.
4 = For all stations set
40-st-01=0
(Barge In not allowed)
40-st-02=0
(Monitor not allowed)
It is strongly recommended that this parameter is used on ALL systems to prevent accidental
Barge In operations being misinterpreted as cross talk. In some software versions these settings
are 0 in default. All other system programming information remains unchanged when using 3 or 4.
6 = Copy Voice prompt from MBU Nand flash to VMU CF card
This parameter transfers AA Greeting messages from the MBU AA Flash to the VMU Flash.
This feature takes several minutes to achieve. Do Not interrupt . When the transfer is in operation the
LED on the VMU and the LED on the MBU adjacent will fast flash until the transfer is complete.
7 = Copy VMU data to Nand Flash on MBU
This parameter transfers AA Greeting messages from the VMU Flash to the MBU Flash.
This feature takes several minutes to achieve. Do Not interrupt . When the transfer is in operation the
LED on the VMU and the LED on the MBU adjacent will fast flash until the transfer is complete.
8 = Reset CF card data on VMU card
9 = Reset DSP
# = update the loader, LCD displays "Update Loader SW", Press [1] to update loader .
Содержание G1E
Страница 16: ...Issue 3 3 2 April 2011 ...
Страница 26: ......
Страница 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Страница 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Страница 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Страница 74: ...58 Issue 3 3 2 April 2011 ...
Страница 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Страница 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Страница 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Страница 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Страница 127: ...G1E Programming Manual 111 ...
Страница 169: ...G1E Programming Manual 153 ...
Страница 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Страница 218: ......