Parameter
Description
Synchronize Environment Data
You are advised to retain the default
value Disable.
NOTE
When this parameter is set to Enable, the
SmartLogger transmits the wind speed and
direction data to the solar inverter in a PV
plant with the tracking system.
Master/Slave
When the SmartLogger connects to
multiple EMIs, set one of them to
master mode. The solar inverter
performance data displayed is the data
of the EMI in master mode.
Signal parameters
NOTE
Signal parameters include Signal Name,
Port number, Lower Thres., Upper Thres.,
Start (V/mA), End (V/mA), and Unit.
Set these parameters as required.
NOTE
When you need to change the configured
port number, set Port number to No first,
then to the required port number.
Step 3 If Port number is set to the number of the connected PT port, click PT T
Correction to correct the temperature.
----End
6.3.18 Setting STS Parameters
The STS can be connected to the SmartLogger over RS485 or FE. If the STS is
connected to the SmartLogger over RS485, you need to manually add devices and
set access parameters. If the STS is connected over FE, the SmartLogger
automatically identifies the STS.
Procedure
Step 1 (Optional) If the STS connects to the SmartLogger over RS485, click Add Device
and set access parameters.
SmartLogger3000
User Manual
6 WebUI Operations
Issue 10 (2022-08-20)
Copyright © Huawei Technologies Co., Ltd.
179