6.3.17 Setting EMI Parameters
6.3.17.1 Setting Modbus-RTU EMI Parameters
Procedure
Step 1 Set access parameters and click Add Devices.
Figure 6-54 Setting access parameters
Parameter
Description
Device Type
Set this parameter to EMI.
Connection mode
Set this parameter to Modbus-RTU.
Port number
Set this parameter to the serial number of the COM
port connected to the EMI.
Address
Set this parameter to the communication address of
the EMI.
Step 2 Choose Monitoring > EMI > Running Param., set running parameters and click
Submit.
●
If the model of the connected EMI is displayed in the EMI model drop-down
list box, set parameters as follows.
Parameter
Description
EMI model
Set this parameter to the model of the connected EMI.
Synchronize
Environment Data
You are advised to retain the default value Disable.
NOTE
When this parameter is set to Enable, the SmartLogger
transmits the wind speed and direction data to the solar
inverter in a PV plant with the tracking system.