Device
Type
Parameter Description
Start From
(U)
Position in which the controller enclosure or disk
enclosure resides. The unit is U which is counted from
bottom up.
Device
height
Height of a single enclosure. The unit is
U
.
Clustered
NAS
Engine
Cluster
Name
Name of the current cluster.
Node
quantity
Quantity of cluster NAS engine nodes. The value can be
an integer from 2 to 24.
Start
physical IP
address
Start physical IP address of the clustered NAS engine.
The value can be either imported from the configuration
file or manually entered.
Start
virtual IP
address
Start virtual IP address of the clustered NAS engine. The
value can be either imported from the configuration file
or manually entered.
Manageme
nt IP
address
Management IP address of the clustered NAS engine.
Subnet
mask
Address of the subnet mask.
Gateway
Address of the clustered NAS engine gateway.
DNS
server IP
address
IP address of the clustered NAS engine's DNS server. It
is generally the IP address of the domain control server.
This parameter is optional.
DNS
domain
name
Name of the clustered NAS engine's DNS server. It is
generally the name of the domain control server.
This parameter is optional.
Clustered
NAS
Engine
Nodes
Switch
SN
An SN tag that is attached in the mounting ear on the right
of the front panel. The SN is displayed in the format of
Type: 21XXXXXXXX S/N: ZXXXXXXXXX. When
filling out the template, combine these two parts as
21XXXXXXXXZXXXXXXXXX.
Rack ID
ID of the cabinet in which the clustered NAS engine
enclosure.
Start From
(U)
Position in which the clustered NAS engine enclosure
resides. The unit is U which is counted from bottom up.
Device
height
Height of a single enclosure. The unit is
U
.
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
9 System Initialization
Issue 02 (2015-09-22)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
242