Troubleshooting
3 Co mmon Troubleshooting Methods
Issue 02 (2012-02-29)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
72
CLI Mode
Step 1
Run the
network -auto-check on
to enable the automatic check function.
The command is as follows:
TERMINAL(config)#
network-auto-check on
If the IP address of the SIP server or M GC server, and the IP address of the device t o be checked are
not set, the IAD does not check the connection automatically.
If the SIP server's or M GC server's IP address is set but the device's IP is not set, the IAD
automatically check the connection with the first set SIP server or M GC server.
Step 2
Run the
network -auto-check ipaddress
ip-address
to set the IP address of a device to be
checked.
The command is as follows:
TERMINAL(config)#
network-auto-check ipaddress 192.163.1.8
Step 3
Run the
write
command to save the settings.
The command is:
TERMINAL(config)#write
Step 4
Run the
display network -auto-check
command to check the configuration.
The command is as follows:
TERMINAL(config)#display network-auto-check
----------------------------------------
server ipaddress:192.163.1.8
network-auto-check:on
----------------------------------------
Step 5
Query the network status according to the alarm information. For details, see
Processing IAD
Alarms
.
The information is as follows:
IAD2000(config)#display alarm history alarmid 0x06010007
Command:
display alarm history alarmid 0x06010007
ALARM 38 FAULT WARNING 0x06010007 COMMUNICATION 2010-12-09 10:02:38
ALARM NAME : Network-autocheck fault
PARAMETERS : netcheck-ip : 192.163.1.8
DESCRIPTION : Network-autocheck fault //Fault indicates network abnormality
CAUSE : Request timed out.
ADVICE : Request timed out.
--- END
The information indicates that the connection between the standby SIP server and the IAD is
restored.
Step 6
Rectify the network fault. For details, see the
IAD Troubleshooting Guide
.
Query the alarm information again. The information is as follows: