eSpace IAD
Troubleshooting
2 Analy zing and Rectify ing Faults
Issue 02 (2012-02-29)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
44
2.3.7 IAD Cannot Register with the UCEMS After Startup
Symptom
Network:
UCEMS Client- UCEMS Server-IAD
The IAD online indicator on the UCEMS is gray. The IAD cannot be registered with the
UCEMS.
Cause
The possible causes are as follows:
Network exceptions occur.
The physical serial number of the IAD is inconsistent with that set on the UCEMS.
The IAD is disconnected from the UCEMS or the handshake function is disabled.
The IAD uses an IP address for registration but the IP address setting is incorrect.
The IAD uses a domain name for registration but the domain name fails to be parsed.
Solution
Step 1
Check whether the network quality is good.
If no, rectify the network fault.
If yes, go to
Step 2
Run the
display physical-serial-num
command to verify that the physical serial number is
the same as that set on the UCEMS. To obtain the physical serial number set on the UCEMS,
contact the network administrator. If the configuration is inconsistent with that on the
UCEMS, run the
physical-serial-num
string
command in the global configuration mode to
synchronize the physical serial number.
Step 3
Run the
display nms
command to verify that the communication parameter values set on the
IAD are the same as those set on the UCEMS. If the values are different, run the
nms
command to set the communication parameters.
Step 4
If
nms access value
is
Disable
, run the
nms access on
command to allow the IAD to access
the UCEMS. Run the
nms handshake switch on
command to enable the handshake function
to ensure that the IAD information on the UCEMS is latest.
Step 5
Check whether the fault is rectified.
If yes, the procedure ends.
If yes, go to
Step 6
Contact Huawei technical support.