COMBI521
EN - 98
26. Connect the instrument to the adapter as shown in the
diagram on the display (input
B4
to input
N
, input
B3
to
input
E
and input
B1
to input
L1
).
Use the three
selectors of the adapter and set the following
positions:
PP State
NC
CP State
A
Fault
OK
STS
15/10 – 18:04
3/6 – Checking status A
27. Press the
GO/STOP
key. The following screen appears
on the display. Notice the presence of the status “
A
”
corresponding to the position “STATUS”
STS
15/10 – 18:04
L1-N
= - - - V CP = - - - V
L1-PE
= - - - V F
= - - - Hz
N-PE
= - - - V I
= - - - A
A
STATUS
28. Press the
GO/STOP
key. The result of measurements is
shown in the screen on the side. The instrument displays
the message "
OK
" in case of a positive result of the tests
(see Table 3)
STS
15/10 – 18:04
L1-N
= 0 V CP = 12.0 V
L1-PE
= 0 V F
= 0 Hz
N-PE
= 0 V I
= 0.0 A
OK
A
STATUS
29.
Press the
SAVE
key to partially save the test, and to carry on with the subsequent test
(no. 32).
30. The instrument displays the message "
FAIL
" in case of a
negative result of at least one test (see Table 3)
STS
15/10 – 18:04
L1-N
= 21.5 V CP = 12.0 V
L1-PE = 0 V F
= 0 Hz
N-PE = 0 V I
= 0.0 A
FAIL
A
STATUS